Communication configuration: 19200, N, 8, 1Slave address: 1

Offset address Reading/Writing Chinese (unit) Example (integer)
16 12304 RW amplitude(%) 10~100
17 12305 RW Delay time (ms) 100~9999
18 12306 100~9999
19 12307 RW Welding time (ms) 100~9999
20 12308 100~9999
21 12309 RW Cooling time (ms) 100~9999
22 12310 100~9999
23 12311 RW Shaking time (ms) 100~9999
24 12312 100~9999
29 12325 RW Frequency limit 14000~40000
30 12326 RW Frequency lower limit 14000~40000
31 12329 RW model 0: Time Mode 1: Spot Welding Mode 2: External Control Mode
Offset address Reading/Writing Chinese (unit) Example (integer)
0 16384 R state 0 standby 1. At work 2 Emergency Stop 3. In the test 4. Scanning 5. In the process of mold adjustment6 alarms
1 16385 R model 1: Automatic 0: Mold Adjustment
2 16386 R Current (mA) 0~10000
3 16387
4 16388 R Power (mW) 0~10000000
5 16389
6 16390 R Main frequency (Hz) 14000~40000
7 16391
12 16396 R Yield 0~99999999
13 16397
14 16398 R abnormal 0: Frequency unlock1: System overload2: Output disconnected3: System emergency stop4: Power exceeded limit5: Impedance exceeds limit
Offset address Reading/Writing Chinese (unit) Example (Integer)(0x represents hexadecimal)
0 20480 W model 0xA0: Frequency sweep0xB1: Manual0xC2: Automatic0xD3: Test0x00: Stop0x01: Clear alarm
2 20482 W Reset production count Write any value